Essential Requirements for CE Compliance

Conditions 1-5 listed below must be satisfied for LPM20 drives to meet the
requirements of EN61800-3:

1. Standard LPM20 CE compliant drive.

2. Grounding as described in

Grounding the Drive on page 1-13

.

3. Output power wiring to the motor, and all control/signal wiring must use

braided shielded cable with a shield coverage of 75% or greater, or metal
conduit.

4. The shields of all shielded cables must be terminated with the proper

connectors to chassis/earth.

5. Motor cables must not exceed 20 meters (65.6 feet) in length.

C-Tick Conformity

Compliance of LPM20 drives with the Australian Radiocommunications
Act of 1992 has been demonstrated through compliance with EN61800-3.
Both the General Notes and the Essential Requirements for CE Compliance
provided above apply to C-Tick compliance for LPM20 drives.

C-Tick Declarations of Compliance are available online at:
http://www.ab.com/certification/c-tick/index.html