Chapter 5 – specifications & dimensions – Rockwell Automation 161 SERIES B FRN 2.001 User Manual

Page 43

Advertising
background image

39

Chapter 5 – Specifications & Dimensions

Technical Data

Series

Bulletin 161

Type

A01

A02

A03

A04

A05

A07

A10

A15

Drive rating kW (HP)

0.2 (0.3)

0.4 (0.5) .55 (.75) 0.75 (1) 1.1 (1.5) 1.5 (2)

2.2 (3)

3.7 (5)

115V Input rated current (A)

5.5

10.0

N/A

16.0

N/A

N/A

N/A

N/A

230V 1F Input rated current (A)

3.1

5.8

6.7

9.0

11.2

16.0

22.5

N/A

230V 3F Input rated current (A)

1.8

3.4

3.9

5.2

6.5

9.3

13.0

20.0

Output rated current (A)

1.4

2.6

3.0

4.0

5.0

7.1

10.0

15.9

Power Dissipation (W)

17

29

33

41

53

70

101

169

Mass (kg)

See dimension drawings on following page.

Input voltage (V)

200 V -10% to 240 V + 5%, 50/60 Hz +/- 5%; 100V -5% to 120V +5%

Output voltage

3

Φ

adjustable from 0 to 230V

Type of protection

IP20

PWM carrier frequency

0.5 - 16 kHz

V/Hz characteristics

Programmable V/Hz ratio, V/Hz control (constant torque, variable torque)

Type of control

Voltage-driven, PWM sine weighted, IGBT-Power module

Output frequency

0.5 - 360 Hz

Accuracy of frequency
command

Digital:

+/- 0.01% of max. frequency

Analog: +/- 0.2% of max. frequency

Frequency resolution

Digital: 0.1 Hz, analog: 0.01% of max. frequency

Overload capacity

Software: 150% for 60 s (once in a period of 10 min.), Hardware: 220%

Starting torque

min. 150% at frequencies >3 Hz

DC brake

Starting frequency, braking torque, running times are variable.

Analog inputs

0 -10 V, input impedance 10 k

4 - 20 mA, input impedance 250

PTC input

Digital inputs

5 programmable level triggered inputs, 24V PNP logic, NO or NC contacts

Analog outputs

1 programmable output. 0-10V, 1mA, Accuracy: +/- 5% for frequency, +20% for
current.

Digital outputs

2 open collector outputs. 27VDC, 50mA

Relay output

1 fault indication relay (change-over contact)
Resistive rating: 2.5A at 250VAC – 3A at 30VDC
Inductive rating: 0.2A at 250VAC – .7A at 30VDC

Protection functions

Over-current, over-voltage, under-voltage, electronic motor protection, over-
temperature, ground fault, overload etc. (see Chap.4).

Other functions

15 preset speeds, PID control, unintentional start protection, RS422 serial interface,
skip frequencies etc.

Ambient temperature

-10 - +40 °C (up to +50 °C by removing top cover, reducing carrier frequency to
2kHz, and derating output current by 20%)

Relative humidity

20 - 90% relative humidity, no condensation

Vibration/Shock

Vibration: 0.6G operational / Shock: 10.0G operational

Max. installation altitude

1000 m (3300 ft.) above sea level

Options

Line filter modules

Standards

EN 61800-3 EMC guidelines in connection with optional line filter modules
in line with installation guidelines, EN 50178 Low-Voltage guideline,

Advertising