Chapter 2 – Installation & Wiring

Storage and Operating Conditions

Follow these recommendations to prolong drive life and performance:

Store within an ambient temperature range of –25

o

C to 70

o

C.

Store within a relative humidity range of 20 to 90%, non-condensing.

Avoid storing or operating the drive where it could be exposed to a corrosive atmosphere.

Protect from moisture and direct sunlight.

Operate within an ambient temperature range of –10

o

C to 40

o

C.

IMPORTANT: To operate the drive between 40

o

C and 50

o

C, make the following adjustments:

Reduce the carrier frequency to 2kHz

Reduce the output current to 80% of the drives rated current

Remove the debris cover from the top of the drive

CE Compliance

Refer to Appendix A – CE Conformity.

Installation

Mount the drives on a flat, vertical and level surface. Drive orientation must be vertical (top up) for
proper heat dissipation.

Install the drive with screws, recommended screw sizes are listed in the table below. Note that
ratings AA01-AA03 require screws at the upper left and lower right corners only.

Ensure that debris cover is in place when installing the drive to prevent filings, cable insulation and dust
from entering the drive.

Clearances

The drive should be installed using the minimum clearances shown in Figure 2.1.

Figure 2.1 Bulletin 161 Minimum Clearances and Airflow

Description

Metric

English

Mounting Torque

1.2 – 1.3 Nm

10.6 – 11.5 lb.in.

Mounting Base Screws

M4 x 0.7

#8-32

100 mm

100 mm

30 mm

Air

30 mm

Circulation

(3.94 in)

(1.18 in)

(3.94 in)

(1.18 in)

Advertising