Mounting Isolation Switch
3) From the inside of the cabinet, insert the handle through the cut-out and
Handle Module (cont.)
line up the pilot holes with the pre-drilled holes in the handle assembly.
Use four (4) ¼-20 (6.3 x 1.8 Type B) self-tapping screws to attach the
front of the handle. Torque the screws according to the specifi cations
shown on page 1-4.
4) Mark the location of the rear mounting tabs of the handle module. Drill
two (2) 0.219-in. (5.5mm) pilot holes (see Figure 2.4).
0.125
[3]
Clearance
22.67
[576]
4.61
[117]
13.00
[330]
19.93
[506]
26.23
[666]
FRONT VIEW
(Cut away to show lower mounting holes)
LEFT SIDE VIEW
Front
Mount
ing S
urf
ace
Rear Mount
ing S
urf
ace
4 X Ø 0.219
Mounting Holes
Grounding Wire
2 X Ø 0.312
Clearance Holes
See Fig. 2.3
for Punching
Dimensions
(All dimensions in inches [millimeters])