Component Installation 2-5

1503-IN050E-EN-P – June 2013

5) Install two (2) ¼-20 (6.3 x 1.8 Type B) self-tapping screws in the tabs

at the end of the handle module to attach it to the rear of the cabinet.

Torque the screws according to the specifi cations shown on page 1-4.

The rear mounting tabs may deform slightly when

secured to the mounting surface. The deformation is

normal and helps to reduce any gap between the handle

module and the mounting surface.

6) Connect the green grounding wire to a suitable grounding surface.


Mounting Isolation Switch

Refer to the component layout shown in Figure 2.1 or 2.2 to determine the

and Trailer Fuse Block

location of the isolation switch. Refer to Figure 2.6 to determine the

location of the mounting holes for the isolation switch.

Inter-phase Barriers

Clearance Holes

Auxiliary Contacts

Dome Plugs

Shaft

Grounding Bar

Figure 2.5 – Typical Isolation Switch

Required Hardware:

– Eight (8) ¼-20 x 1.0 in. (6.3 x 1.8 x 25mm Type B) self-tapping screws

– Four (4) dome plugs (supplied)

1) Drill four (4) 0.219 in. (5.5 mm) pilot holes in the mounting surface at

Location A as shown in Figure 2.6 for the isolation switch.

2) Attach the isolation switch using four (4) ¼-20 (6.3 x 1.8 Type B)

self-tapping screws. Torque the screws according to the specifi cations

I M P O R T A N T

I M P O R T A N T