Door interlock assembly (cont.) – Rockwell Automation 1503 OEM Starter Frame Components Installation Manual User Manual

Page 24

Advertising
background image

2-16

Component Installation

1503-IN050E-EN-P – June 2013

All mounting hardware for the Door Interlock Assembly

is supplied. Metric equivalents are provided should the

user wish to substitute metric hardware.

1) See Figure 2.15 for the mounting dimensions for the door interlock

assembly.

2) Drill two (2) 0.172 in. (4.6 mm) pilot holes on the right side of the door

for the Z-clip.

3) Drill two (2) 0.219 in. (5.5 mm) pilot holes on the front of the door for

the cover catch mounting bracket.

1.95

[49]

1.55

[39]

3.13

[80]

0.35

[9]

0.88

[22]

TOP VIEW

FRONT VIEW

See Fig. 2.3

Customer

supplied door

Customer supplied

structure

0.84

[21]

MAX.

2.11

[54]

MIN.

2 X Ø 0.219 [5.31]

Pilot Holes

(For rib-necked

carriage bolts)

3.38

[86]

3.50

[89]

0.65

[17]

RIGHT SIDE VIEW

2 X Ø 0.172 [4.09]

Pilot holes

Customer

supplied door

Customer supplied

structure

Figure 2.15 – Mounting Locations for Door Interlock Assembly

4) Attach the Z-clip using #10 (4.8 x 1.6 Type B) self-tapping screws, but

do not completely tighten them.

5) Attach the cover catch mounting bracket using #10-32 x 0.500

(M5 x 0.8) rib-necked carriage screws, lockwashers and hex nuts.

6) Attach the cover catch to the cover catch mounting bracket using the

supplied #10-32 x 0.219 pan-head machine screw.

The pilot holes in the cover catch are threaded. To avoid

damaging the thread, use the hardware provided to attach

the cover catch to the mounting bracket.

I M P O R T A N T

I M P O R T A N T

(All dimensions in inches [millimeters])

I M P O R T A N T

I M P O R T A N T

Door Interlock Assembly

(cont.)

Advertising