Optional rs-232 communication – Rockwell Automation 1404-M4_M5_M6_M8 Powermonitor 3000 Master Module Installation Instructions User Manual

Page 39

Advertising
background image

Powermonitor 3000 Master Module 39

Publication 1404-IN007F-EN-P - November 2009

Optional RS-232 Communication

Powermonitor 3000 units with a catalog number ending in -232 are equipped with an RS-232
serial communication port in addition to the native RS-485 port. The RS-232 communication
standard supports point-to-point communication among two stations or nodes. You must
select either optional RS-232 communication or native RS-485 communication. The two
ports do not operate at the same time.

The optional RS-232 communication port is a data communication equipment (DCE) type
device. It requires a straight-through RS-232 cable to connect with personal computers,
programmable controller serial ports, and other data terminal equipment (DTE) devices. It
requires a crossover cable for connection to a modem or other DCE devices. No terminating
resistor is required.

The maximum cable length is 15.24 m (50.0 ft). Refer to the following wiring diagrams for
cable pinout information for constructing your own cable using DB-9 and/or DB-25
connectors.

Connecting Powermonitor 3000 Unit to Computer Communication Port

Powermonitor 3000

5

9

6

1

2

1

3

4

7

8

9

6

5

TXD

No connect

No connect

No connect

RXD

RTS (See Note 1)

CTS (See Note 1)

DSR (See Note 2)

GND

3

2

4

5

7

3

2

2

3

8

7

7

8

5

5

TXD

RXD

CTS (See Note 1)

RTS (See Note 1)

GND

TXD

RXD

RTS (See Note 1)

CTS (See Note 1)

GND

DB9 Female

13

25

14

1

DB-25 Female

5

9

6

1

DB9 Female

5

9

6

1

DB9 Female

Powermonitor 3000 Device

IBM Personal Computer

IBM Personal Computer -

Notes:
1) Required only if you have
enabled hardware handshaking.
2) Internally pulled active in this DCE
device - function not supported.
3) Straight-through RS-232 cable required.

RS-232

Output

Input

Ground

Output

Input

Output

(See Note 3)

Or PLC Processor

Or SLC Processor

Or ControlLogix Processor

IBM Compatible

Personal Computer

SLC 500 Ch 0

PLC-5 Ch 0 - DB-25 Male