Chapter 5 – Programming

5-50

Adapter I/O Group (cont.)

[Data Out A1 through D2]

Parameter # 119 - 126

[Data Out A1 through D2]

Parameter Type Read & Write

These parameters are used to write real real time data
v ues r

he dr ve

des

r er Th s s

These p r

e ers re used

r e re re

e d

values from the drive to a destination controller. This is
accomplished by programming a Parameter Number into
the [Data Out] parameters. The real time value of that
parameter will be written to the input image table of the
destination controller.
IMPORTANT: [Preset Freq 1] through [Preset Freq 7]
are not accessible with these parameters.

Data Out A1
Data Out A2
Data Out B1
Data Out B2
Data Out C1
Data Out C2
Data Out D1
Data Out D2

Bulletin 1305 drive

Controller Input Image Table (i.e. PLC, SLC, etc.)

IMPORTANT: addressing information that defines which controller
I/O address corresponds to a [Data Out] parameter is determined by
the dip switch settings on the external communication module. Refer
to the appropriate Bulletin 1203 Communication Module User Manual
for details.
Refer to Appendix B for additional information.