Table 5.a frequency source selection – Rockwell Automation 1305 AC Drive, Firmware 1.01-3.00 User Manual User Manual
Page 94

Chapter 5 – Programming
5-26
Table 5.A Frequency Source Selection
Parameter Settings
Frequency Source ➀
Control Terminal Block
Accel/Decel
Preset/
2nd
Accel(26)
Upper
Presets
(72)
Freq
Select 1
(5)
Freq
Select 2
(6)
Preset Freq 1
(27)
Preset Freq 2
(28)
Preset
Freq 3
(29)
Preset
Freq 4
(73)
Preset Freq 5
(74)
Preset
Freq 6
(75)
Preset Freq 7
(76)
SW3
TB2-18
SW2
TB2-17
SW1
TB2-16
•
0
0
0
•
0
0
X
•
0
X
0
Disabled
•
0
X
X
Disabled
➁
•
X
0
0
•
X
0
X
•
X
X
0
Whe y u se p r
e er
Preset
•
X
X
X
When you set parameter
26 to “Preset,” only Accel
T e
d De e T e
Preset
➁
•
0
0
0
26 to “Preset,” only Accel
Time 1 and Decel Time 1
can be used.
•
0
0
X
can be used.
•
0
X
0
Ena led
•
0
X
X
Enabled
•
X
0
0
•
X
0
X
•
X
X
0
•
X
X
X
➀
The parameter [Freq Source] indicates the active frequency source. See p. 5-40.
➁
Factory default settings.
•
Indicates active function/parameter.
X
Indicates closed switch.
0
Indicates open switch.
(26) Indicates parameter number.