Chapter 3 – Human Interface Module
3-9
PROCESS MODE
ACTION
DESCRIPTION
HIM DISPLAY
or
or
or
or
or
ESC
ESC
SEL
press
❏ 1. When selected, the Process mode will show a custom display consisting of
information programmed with the Process Display group of parameters.
a. Complete steps a – c on page 3-7 to access the Program mode.
b. Press the Increment/Decrement key until “Process Display” is shown.
Press Enter.
c. Using the Increment/Decrement keys, select [Process Par] and enter
the number of the parameter you wish to monitor. Press Enter.
d. Select [Process Scale] using the Increment/Decrement keys. Enter the
desired scaling factor. Press Enter.
e. Select [Process Text 1] using the Increment/Decrement keys. Enter the
desired text character. Press Enter and repeat for the remaining
characters.
f. When process programming is complete, press ESC until “Choose
Mode” is displayed. Press Increment/Decrement until “Process” is
displayed. Press Enter to get process value.
g. To save Process Display for power up, simultaneously press Increment
and Decrement keys (on programming panel).
Choose Group
Process Display
Choose Mode
Program
Process Par
1
Process Scale
1.00
Process Text 1
V
Choose Mode
Process
+0.00 V