Troubleshoot the card installation, Troubleshoot the card installation -11, Check for resource conflicts -11 – Rockwell Automation 1784-PCC ControlNet Communication Card Installation Instructions User Manual

Page 61

Advertising
background image

Install and Use the 1784-PCC Card in Windows NT 4-11

Publication 1784-IN034D-EN-P - June 2002

15. Run the 1784-PCC test utility as described in Chapter 6 to verify the

installation.

If installation fails, refer to Troubleshoot the Card Installation on page 4-11.

Troubleshoot the Card Installation

Use the following sections to determine why the test utility failed.

Check for Resource Conflicts

When you run the PCC setup utility in Windows NT, the utility tries to assign free
resources to the PCC card. If your card used to work, and has now stopped
working, it is probably because the resources originally assigned to the card are
now being used by another device you recently added, such as an Ethernet card.
Try re-running the card's setup utility. Refer to Locate the 1784-PCC Driver for
Windows NT on page 4-5
. The utility may be able to automatically find other
resources to assign to the card.

If you do this, and the test utility still fails, you will need to check for resource
conflicts. Possible conflicts include IRQ, memory, or I/O conflicts. To view and
change your resource locations, you will need to view all of your resource
allocations to determine which resouces are free.

To access and change resouce locations:

1. Do one of the following:

• access Windows NT diagnostics (StartProgramsAdministrative

Tools

Windows NT Diagnostics), or

• Select StartRun and type WINMSD in the Run dialog box. Press

Enter or click Ok.

2. To determine if you have an IRQ conflict, click on the Resources tab.