Rockwell Automation 1772-LV Mini-PLC - 2/15 Programmable Controller (Series B) Programming and Operations User Manual

Page 191

Advertising
background image

Quick Reference Section

Appendix A

AĆ22

Function

Description

Mode

Key Sequence

[INSERT]

[T.END]

Position the cursor on the instruction that will

precede the temporary end instruction. The

remaining rungs, although displayed and

accessible, are not scanned.

Removing a temporary

end instruction

[REMOVE]

[T.END]

Program

Position cursor on temporary end instruction and

press key sequence.

NOTE: When in test mode, the processor will hold outputs off regardless of attempts to force them on.

Table A.P

Report Generation Commands

Command

Key Sequence

Description

Enter report generation function

[RECORD][DISPLAY] or

Set baud rate,

Message Code Keys)

Puts industrial terminal into report generation

function.

Same (entered from a peripheral device).

Message store

[M][S][,] (Message Number)

[RETURN]

Stores message in processor memory. Use [ESC]

to end message.

Message print

[M] [P] [,] (Message Number)

[RETURN]

Prints message exactly as entered.

Message report

[M][R][,}(Message Number)

[RETURN]

Prints message with current data table values or bit

status.

Message delete

[M][D][,] (Message Number)

[RETURN]

Removes message from processor memory.

Message Index

[M][I][RETURN]

Lists messages used and the number of words in

each message.

Automatic report generation

[SEARCH][4}[0} or

[M][R][RETURN]

Allows messages to be printed through program

control.

Same (entered from a peripheral device).

Exit automatic report generation

[ESC] or [CANCEL COMMAND]

Terminates automatic report generation.

Same (entered from a peripheral device).

Exit report generation function

[ESC] or [CANCEL COMMAND]

Returns to ladder diagram display.

Same (entered from a peripheral device).

NOTE: [CANCEL COMMAND] can only be used if the function was entered by a command from a peripheral device.

Advertising