Mini-PLC-2/15 System:

An Overview

Chapter 3

3Ć6

Terminal Strip

Purpose: Provides wire connections for the power supply module.

Hardware: Terminals L1 and L2 label the AC input connections.

Battery Backup

Purpose: Provides battery backup power for the processor’s memory.

Power Supply: Two alkaline D size battery cells or one D size lithium battery
cell.

Function: Guards against the loss of memory if the:

AC power line fails
Power supply fails

Transport Cable

Purpose: Allows the controller to be moved from the I/O chassis without
memory loss.

Function: It electrically connects the battery pack of the system power supply
to the processor module for transporting.

Hardware: Cat. no. 1772-CD transport cable (2 ft/6 cm)

CAUTION: Do not remove the processor module or install the
processor module when the system’s power is on. This could
alter memory content and you must re-enter your program.

Switch Group Assembly

Purpose: Determines output response to a malfunction detected by the
controller.

Location: Left side of the I/O chassis backplane.

Quantity: 8 per switch group assembly. Switches 2-8 are not used with this
controller.

Response:

On indicates that the outputs are left in their last state when a fault is

detected. machine operation can continue after fault detection.