Press, More menu options appear. 4. press, The following display appears – Rockwell Automation 1747-PTxx Getting Started Guide for HHT User Manual

Page 30

Advertising
background image

Chapter 3
Creating a Program

Getting Started Guide

for HHT

3–5

Clearing the Memory of the HHT

To create a new program, you must clear the HHT memory (DEFAULT
program).

1. Energize your HHT. After the HHT goes through self–diagnostic tests,

the following display appears

:

SLC 500 PROGRAMMING SOFTWARE Rel. 2.03

1747 – PTA1E

Allen–Bradley Company Copyright 1990

All Rights Reserved

F1

F2

F3

F4

F5

PRESS A FUNCTION KEY

SELFTEST

TERM PROGMAINT

OFL
UTILITY

2. Press

[F3] – PROGMAINT

. Either the following display appears (if a

program is in the HHT), or. . .

File Name:

Prog Name:2345

File Name

Type Size(Instr)

0

System 76

1

Reserved 0

2

Ladder 5

F1

F2

F3

F4

F5

CHG_NAM CRT_FIL EDT_FIL

OFL
MEM_MAP

DEL_FIL

>

2345

(or anything other

than

DEFAULT

) indicates

that a program is in the HHT.

this display appears (if a program is not in the HHT).

File Name:

Prog Name:DEFAULT

File Name

Type Size(Instr)

0

System *

1

Reserved *

2

Ladder *

F1

F2

F3

F4

F5

CHG_NAM CRT_FIL EDT_FIL

OFL
MEM_MAP

DEL_FIL

>

DEFAULT

indicates that a

program is not in the HHT.

Clear the memory as follows, even if the DEFAULT program is present.

3. Press

[ENTER]

. More menu options appear.

4. Press

[F4] – CLR_MEM

. The following display appears

File Name:

Prog Name:2345

File Name

Type Size(Instr)

0

System 76

1

Reserved 0

2

Ladder 5

ARE YOU SURE?

F1

F2

F3

F4

F5

YES

OFL

NO

5. Press

[F2] – YES

. This clears the HHT memory. Now you are ready to

create a program.

Advertising