Rockwell Automation 1747-PTxx Getting Started Guide for HHT User Manual

Page 37

Advertising
background image

Chapter 3
Creating a Program

3–12

Entering an “Examine if Closed” Instruction

1. Press

[F1] – INS_INST

. The following display appears:

F1

F2

F3

F4

F5

2.0.0.0.*

BIT

TMR/CNT

I/O_MSG

CPT/MTH

OFL

>

COMPARE

<END>

2. Press

[F1] – BIT

. The following display appears:

F1

F2

F3

F4

F5

2.0.0.0.*

>

] [

( )

]/[

( )

L

OFL

( )

U

<END>

3. Press

[F1] —] [—

. The following display appears:

ENTER BIT ADDR

:

ZOOM on XIC
NAME:

EXAMINE IF CLOSED

BIT ADDR:

F1

F2

F3

F4

F5

] [

2.0.0.0.*

Note that the HHT
“shifts” for you.

4. At the

ENTER BIT ADDR:

prompt, type the address

I:1/0

, then

[ENTER]

.

(If you entered the wrong instruction by mistake, just press

[ESC]

and try

again.)

5. Press

[F5] – ACCEPT

. This accepts the address. The following display

appears:

F1

F2

F3

F4

F5

] [

( )

]/[

( )

( )

>

L

OFL

U

2.0.0.0.*

<END>

] [