Command Initiation, Execution, and
Monitoring
Chapter 7
7-12
Figure 7.6
FAULT Bit Diagnostic Rungs (Single Command Example)
033 00
Local Fault
L
01000
OFF
03310
Remote Fault
Indicator
Output
U
010 00
03200
Done
Indicator
Output
The method of Figure 7.6 can be extended to monitor multiple commands
from a station, controlling multiple output indicators as necessary.
However, where more than one command is being sent from a station, the
use of multiple output indicators may not be practical. In this instance, a
single output indicator can be used to signal all REMOTE or LOCAL
FAULT conditions for commands from that station. Figure 7.7 shows a
method for fault indicator control assuming multiple commands.