36 Read and Write Configuration Maps for the FLEX I/O Module

Map Data for the Module

The following read and write words and bit/word descriptions describe the
information written to and read from the frequency input module. The
module uses up to 6 words of input data and up to 7 words of output data.
Each word is composed of 16 bits.

Frequency Input Module Image Table Mapping

Module Image

I/O Image

Frequency Channel 0

% Full Scale or Acceleration Channel 0

Diagnostics

Input size

Output size

0...7 Words

1...6 Words

Frequency Channel 1

% Full Scale or Acceleration Channel 1

GS

1

F/A

1

WO

1

MPA

1

DIR

1

GS

0

F/A

0

WO

0

MPA

0

DIR

0

R

R

R

Reserved

FR

1

MPM

1

R

NOPTS

1

LF

FR

0

MPM

0

NOPTS

0

SSM

CF

Minimum Freq or Absolute Value of Acceleration Channel 0

Frequency Scaling Divisor Channel 0

Frequency Scaling Multiplier Channel 0

F/A

AS0

WOFM

0

IS

UP0

MPDM

0

MFST

0

ACT 0

IFI

0

IGI

0

WOFF

0

WOFG

0

Minimum Freq or Absolute Value of Acceleration Channel 1

Frequency Scaling Divisor Channel 1

Frequency Scaling Multiplier Channel 1

F/A

AS1

WOFM

1

IS

UP1

MPDM

1

MFST

1

ACT 1

IFI

1

IGI

1

WOFF

1

WOFG

1

45351

Block Transfer Read Word Assignments

(Octal Bit)

17

16

15

14

13

12

11

10

07

06

05

04

03

02

01

00

Decimal Bit

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

0

Frequency 0…32,767 or 0.0…3,276.7 Channel 0

1

% Full Scale 0.0%…3,276.7% Channel 0 or Acceleration -32,768…+32,767 Channel 0

2

Frequency 0…32,767 or 0.0…3,276.7 Channel 1

3

% Full Scale 0.0%…3,276.7% Channel 1 or Acceleration -32,768…+32,767 Channel 1