Compatible keying – Rockwell Automation 1756-LSC8XIB8I ControlLogix Low-speed Counter Module User Manual

Page 63

Advertising
background image

Rockwell Automation Publication 1756-UM536A-EN-P - April 2012

63

Electronic Keying

Appendix A

Exact Match keying is also necessary to enable Automatic Firmware Update for
the module via the Firmware Supervisor feature from a Logix5000 controller.

Compatible Keying

Compatible Keying indicates that the module determines whether to accept or
reject communication. Different module families, communication adapters, and
module types implement the compatibility check differently based on the family
capabilities and on prior knowledge of compatible products.

Compatible Keying is the default setting. Compatible Keying allows the physical
module to accept the key of the module configured in the software, provided that
the configured module is one the physical module is capable of emulating. The
exact level of emulation required is product and revision specific.

EXAMPLE

In the following scenario, Exact Match keying prevents I/O
communication
.

The module configuration is for a 1756-IB16D module with module revision
3.1. The physical module is a 1756-IB16D module with module revision 3.2.
In this case, communication is prevented because the Minor Revision of the
module does not match precisely.

IMPORTANT

Changing electronic keying selections online may cause the I/O
Communication connection to the module to be disrupted and may result in a
loss of data.

Module Configuration

Vendor = Allen-Bradley
Product Type = Digital Input Module
Catalog Number = 1756-IB16D
Major Revision = 3
Minor Revision = 1

Physical Module

Vendor = Allen-Bradley
Product Type = Digital Input Module
Catalog Number = 1756-IB16D
Major Revision = 3
Minor Revision = 2

Communication is prevented.

Advertising