Chapter 7

Creating Custom Runtime Displays

7 – 5

Tool Display Setting: With the

Envir/Cam

System

Tool Display:

box set to

ON

, all viewports are displayed which have an assigned

display page and number in common with the currently selected viewport.
With

Tool Display:

box set to

OFF

, only the current viewport is

displayed (see “Selecting Display Pages and Page Numbers” in this
chapter).

Pick the

Define Viewport

. . . box to access the

Define Viewport

menu

(see Figure 7.3).

Figure 7.3 Example Custom Runtime Display

Define Viewport box

Define Viewport menu

Using the

Define Viewport

Menu

With the

Define Viewport

menu displayed, you have access to the following

menu items:

Type:

Select the viewport type –

Text

,

Tool

, or

Graph

.

Pick & Place:

Adjust the viewport size and position.

(Disabled if

Tool

is the selected viewport

type)

Border:

*

Set the color of the viewport display border.

Backg.:

*

Set the color of the viewport display background area.

Display Pages:

Select the type(s) of runtime display that will display

the viewport.

Page #:

Select the page number(s) of the runtime display(s) that will

display the viewport.

Erase Port Data:

Permanently remove the contents of the viewport.