Wiring the aec, Wiring cable flying leads to the plugs – Rockwell Automation 4100 AEC Absolute Encoder Converter Installation User Manual

Page 29

Advertising
background image

Publication 4100-UM052B-EN-P - October 2001

Installation & Hook-Up 21

Wiring the AEC

There are several connectors on the front of the AEC. All are
duplicated for each axis except the power input connector. Each axis
has two five-pin plugs for connecting the SSI transducer and two
four-pin plugs for connecting a control. In the center is a 2-pin plug
for the power cable. The flying leads wire directly to the screw
terminals on the plugs.

Wiring Cable Flying Leads to the Plugs

To wire the cable leads to the plug:

1. Look at the plug to make sure the terminal is open. The

following figure shows both an open and a closed terminal.

Figure 8 Terminal diagram

2.

3. Using a small, flat-head screwdriver, turn the clamping screw

counter-clockwise several times.

4. Using a proper stripping tool, strip the wire insulation back on

the cable lead.

5. Trim the cable lead so that 0.275 inches of metal wire is

exposed.

6. Insert the cable lead in the appropriate terminal. Refer to the

proper figures for their locations.

Terminal Steps

If the terminals are:

Do this:

Not open

Go to step 3

Open

Go to step 4

IMPORTANT

All terminals accommodate a maximum of 14 gauge
wire.

Terminal open

Terminal closed

Clamping screws

Advertising