Figure 13
AEC Front
Panel

Figure A.1 shows the connector locations for the AEC. The following
tables provide the pin numbers and their respective descriptions.

SSI Connector

Plug A

Plug B

10 = Clock +

5 = Clock -

9 = Data +

4 = Data -

8 = Shield

3 = Transducer Power +5V DC

7 = Transducer Power Return

2 = Transducer Power +15V DC

6 = Shield

1 = Transducer Power +24V DC

Control Connector

Plug A

Plug B

8 = Reference +

4 = Reference -

7 = N/O Fault Relay Contact

3 = N/O Fault Relay Contact

6 = N/C Fault Relay Contact

2 = N/C Fault Relay Contact

5 = Shield

1 = Shield

Encoder Connector

Plug A

Plug B

12 = Z -

6 = Z + (Blue)

11 = B -

5 = B + (Green)

10 = A -

4 = A + (White)

9 = Strobe -

3 = No Connection

8 = Reference Shield Input

2 = Strobe +

7 = Reference - Input

1 = Reference + Input

Advertising