Configuration Switch B
Transducer Turns, Data Format, & Operation Mode
Transducer Turns, Data Format, & Operation Mode
Switch Setting
Turns
Data Code
Operation Mode
0
Single
Grey
Locked
1
Reserved for future use
2
Single
Grey
Free Run
3
Reserved for future use
4
Single
Binary
Locked
5
Reserved for future use
6
Single
Binary
Free Run
7
Reserved for future use
8
Multi
Grey
Locked
9
Reserved for future use
A
Multi
Grey
Free Run
B
Reserved for future use
C
Multi
Binary
Locked
D
Reserved for future use
E
Multi
Binary
Free Run
F
Reserved for future use
IMPORTANT
All Allen-Bradley 842A Encoders set for grey output
must have Configuration Switch B set to 0. All
Allen-Bradley 842A Encoders set for binary output
must have Configuration Switch B set to 4.
ATTENTION
!
The Compact and 1394 motion controllers must use the
LOCKED mode of operation.