Configuration switch b – Rockwell Automation 4100 AEC Absolute Encoder Converter Installation User Manual

Page 39

Advertising
background image

Publication 4100-UM052B-EN-P - October 2001

Setup 31

Configuration Switch B

Transducer Turns, Data Format, & Operation Mode

Transducer Turns, Data Format, & Operation Mode

Switch Setting

Turns

Data Code

Operation Mode

0

Single

Grey

Locked

1

Reserved for future use

2

Single

Grey

Free Run

3

Reserved for future use

4

Single

Binary

Locked

5

Reserved for future use

6

Single

Binary

Free Run

7

Reserved for future use

8

Multi

Grey

Locked

9

Reserved for future use

A

Multi

Grey

Free Run

B

Reserved for future use

C

Multi

Binary

Locked

D

Reserved for future use

E

Multi

Binary

Free Run

F

Reserved for future use

IMPORTANT

All Allen-Bradley 842A Encoders set for grey output
must have Configuration Switch B set to 0. All
Allen-Bradley 842A Encoders set for binary output
must have Configuration Switch B set to 4.

ATTENTION

!

The Compact and 1394 motion controllers must use the
LOCKED mode of operation.