Publication 4100-UM052B-EN-P - October 2001

30 Setup

Configuration Switch
Tables

Configuration Switch A

ATTENTION

!

The Compact and 1394 motion controllers must use the
LOCKED mode of operation.

Transducer Resolutions

Transducer Resolution

Switch Setting

Counts/Turn

Bits/Turn

0

128

2

7

1

256

2

8

2

512

2

9

3

1024

2

10

4

2048

2

11

5

4096

2

12

6

8192

2

13

7

16384

2

14

8

32768

2

15

9

65536

2

16

A

131072

2

17

B

262144

2

18

C

2097152

2

21

D

4194304

2

22

E

16777216

2

24

F

33554432

2

25

IMPORTANT

All Allen-Bradley 842A Encoders must have
Configuration Switch A set to E.