The ssi connector – Rockwell Automation 4100 AEC Absolute Encoder Converter Installation User Manual

Page 30

Advertising
background image

Publication 4100-UM052B-EN-P - October 2001

22 Installation & Hook-Up

7. Use the screwdriver to tighten the clamping screw to the proper

torque (0.25 N-m/2.2 in-lb.).

8. Verify that the cable lead does not pull out of the terminal.

9.

The function of these connectors, their pinouts, and names are
defined in the following sections.

The SSI Connector

The SSI connectors are used to connect the absolute transducer to the
AEC. The pin layout and functionality for this connector are as
follows.

Cable Leads

If the cable lead:

Do this:

Pulls out of the terminal

Repeat steps 3 through 9
again

Does not pull out of the
terminal

Repeat steps 3 through 9 for
the next terminal

SSI Connector Pin Functions

SSI Input

Pin Number

Pin Function

1

Transducer Power +24V DC

2

Transducer Power +15V DC

3

Transducer Power +5V DC

4

Data -

5

Clock -

6

Shield

7

Transducer Power Return

8

Shield

9

Data +

10

Clock +