Troubleshoot the Pulse
Counter Module
Use this chapter to troubleshoot the pulse counter module by
interpreting the indicators.
The module contains indicators for each of the following:
A
B
C
4 CH PULSE COUNTER MODULE
1794-IP4
AllenĆBradley
0
1
2
3
P
N
P
N
P N
P
N
P D
P
D
P D
P
D
0
1
2
3
A = Power/status indicator – indicates power applied to module and
status of module.
Red – indicates initialization of internal logic at powerup
Green – indicates initialization of internal logic is complete
and correct
B = Insertable label for writing individual I/O assignments.
C = Status Indicators –
Indication Color
Description
P
Yellow
When on, indicates the input is active
N
Yellow
When on, indicates the input is configured for 16-bit period
time measurement and 16-bit accumulating pulse counter
function
D
Yellow
When on, indicates the input is conrfigured for 32-bit period
time measurement