Save and download your, Program, Save and download your program – Rockwell Automation 1758 DataSite Accelerator Toolkit User Manual
Page 34

34
Publication IASIMP-QS008A-EN-P - March 2009
Chapter 3 DataSite and Logix Integration
5. Enter the IP address of
your Ethernet ENBT
module and click OK.
This example uses
192.168.10.90.
6. Click Close to close the Configure Drivers window.
7. Choose RSWho from the
Communications menu.
The RSWho window
opens.
8. Expand AB_ETH_1,
Ethernet until your
1756-L63 Logix controller
is visible.
9. Verify that you can
browse to your Logix
controller in slot 0.
10. Minimize the RSLinx window and return to your RSLogix 5000 project window.
Save and Download Your Program
Follow these steps to save your program and download it to the ControlLogix controller.
1. Click Verify Controller on the RSLogix
5000 toolbar to verify the Logix program.
If any errors or warnings occur, they display at the bottom of the window.
2. Choose Save from the File menu to save the program.
3. Click Who Active.