Scope probe lead extension, Checking your method for effectiveness, Figure 11.6 f – Rockwell Automation System Design for the Control of Electrical Noise User Manual

Page 99

Advertising
background image

Publication GMC-RM001A-EN-P — July 2001

Measuring Noise Reduction Effectiveness

11-9

Scope Probe Lead Extension

Refer to these guidelines, and the figure below, when extending the
scope probe.

Keep the extension cable as short as possible.

Make several turns through the ferrite sleeve.

Only use 1x probes (10x probes will attenuate HF signals by more
than ten times).

Figure 11.6
Extending the scope lead

Checking Your Method for Effectiveness

Connect the probe ground clip to the chosen ground reference and
then connect the probe to the same point. It would be reasonable to
expect zero signal, but it is common to see significant levels of noise.
The main sources of such noise are given below.

Poor ground reference. Refer to the section Grounding Your Probe
(reference ground)
for guidelines.

Scope power supply introducing noise. Refer to the section
Ground Loops for guidelines.

Local magnetic noise field. Refer to the section H-Field Sniffing
Method
f
or details.

Note: It can be seen from this why extending the scope probe

ground wire is not recommended.

Without constant checking, it difficult to know when the observed
noise waveform is real or a measurement artifact.