Chapter 2 Add a PowerFlex 525 Drive to a Controller Project

Test the PowerFlex 525 Drive Tags

1.

Put the controller in RUN mode.

2.

Double-click Controller Tags.

3.

On the Monitor Tags tab, expand the
PowerFlex 525 drive output tag and
change the ClearFaults tag to 1 to clear
any initial faults.

4.

Change the ClearFaults tag back to 0.

5.

Expand the PowerFlex 525 drive input
tag and verify that the Ready tag value is
1.

This tag indicates that the drive is ready
to start.

RUN