6 optional kits – Rockwell Automation FlexPak 3000 DC Drive Version 4.3 User Manual

Page 12

Advertising
background image

1-4

FlexPak 3000 DC Drive Hardware Reference Version 4.3

1.6

Optional Kits

Reliance offers modification kits that broaden the application range of the drive. A
summary of these kits is presented in table 1.1. Not all kits can be used with all drive
model numbers. Refer to the Standard Drives and Control Products catalog (D-406)
for more information.

Table 1.1 – Drive Modification Kits

Name

Description

Model

Number

I/M Number

115 VAC Control
Interface

Converts customer-supplied 115 VAC signals to
24 VDC for operating a FlexPak 3000. Mounts
separately on the panel or can be mounted in the
bottom of a NEMA 1 enclosed drive.

917FK0101

D2-3338

460 VAC to 230 VAC
Conversion Kit

Allows conversion of the 460 VAC FlexPak 3000
to a 230 VAC FlexPak 3000 at one-half the 460
VAC horsepower rating.

916FK series

D2-3329

AC Line Disconnect
Kit

Allows the three-phase line to be disconnected at
the drive. Molded case switch that mounts on the
chassis of the drive or NEMA 1 enclosure.

901FK series

D2-3292,
D2-3365 or
D2-3395

AC Tachometer
Feedback Kit

Allows the FlexPak 3000 to accept feedback
signals from AC tachometers to a maximum
voltage of 275 VAC RMS.

907FK0301

D2-3297

AutoMax Network
Communication Board

Allows the FlexPak 3000 to communicate on the
Reliance AutoMax Distributed Control System
(DCS).

915FK0101

D2-3318

Blower Motor Starter
Kit

Provides a fused AC starter with adjustable
overload and interlocking for control of the three-
phase blower motor used to cool the DC motor.

902FK series

D2-3295

DeviceNet
Communication Board

Allows a FlexPak 3000 to communicate over the
open protocol DeviceNet network. Mounts inside
the FlexPak 3000 and includes terminals for
network connections. You cannot use the
AutoMax Network Communication board when
using the DeviceNet board.

915FK1100

n/a

Drive Control
Configuration
Software for FlexPak
3000

Windows-based software that allows the user to
connect any personal computer running
Microsoft Windows version 3.1 or later to a
FlexPak 3000 drive. Allows you to create, store,
upload, and download drive configurations. You
can also start and stop the drive, monitor and
change parameters through the PC, and read
and reset the drive's fault log.

2CS3000

D2-3348

ControlNet Network
Communication
Board

Allows a FlexPak 3000 to communicate over the
ControlNet network.

915FK2101

D2-3425

Advertising