Rockwell Automation FlexPak 3000 DC Drive Version 4.3 User Manual

Page 36

Advertising
background image

2-22

FlexPak 3000 DC Drive Hardware Reference Version 4.3

2.5.4 Wire the DC Motor to the Drive

Step 1. Size the motor armature circuit conductors for the specific drive rating (see

Appendix A) and according to applicable codes. Use only copper wire rated
60/70

°

C or higher.

Step 2. Locate the DC motor armature and field supply leads on the drive. Refer to

figure 2.18 to 2.21.

Step 3. Connect the DC motor armature leads and the shunt field supply leads to the

drive. See figure 2.22.

Step 4. Tighten armature connections per table 2.4. Field connections should be

tightened to 9 lb-in (1.0 Nm). The tightening torque applies to the wiring
device (stud or terminal board) provided. When an input or output device
(breaker or lug kit) is added, refer to the kit instructions for tightening
specifications.

Figure 2.18 – DC Drive Motor Field and Armature Connection Locations

(1.5 to 30 HP @ 230 VAC /3 to 60 HP @ 460 VAC / 7-110 Amp Rated Output)

Advertising