Rockwell Automation FlexPak Plus DC Drive User Manual

Page 10

Advertising
background image

2:5

Table 2Ć4. Controller Modification Kits. (Continued)

Kit Model

Number

Kit Name

Functional Description

Instruction

Manual

14C223

Voltage/Tachometer Follower

Enables drive to follow a reference source that is indeĆ

pendently generated.

DĆ3971

14C224

Torque Taper

Allows adjustment of slope and break point of drive

speed - torque curves - increases current limit with

speed, i.e. center window.

-

14C225

Test Meter Adapter

Provides a safe and convenient means to measure and

monitor drive regulator analog signals.

DĆ3970

14C226

Automatic Reversing

Enables automatic reversal of the armature loop conĆ

tactors. (requires the drive to be equipped with a reĆ

versing contactor.) In this mode, the motor's energy is

returned to the AĆC line [inverting]. This kit is intended

for very infrequent automatic reversal. If the second

quadrant mode [inverting] is frequently used, an invertĆ

ing fault circuit breaker should be added.

-

14C230

Dancer Follower

Enables automatic control of the drive by a line speed

signal, trimmed by a dancer roll potentiometer.

DĆ3966

14C232

Major Loop Tuning

Allows the User to change the proportional and integral

gain of the major loop.

14C233

Dancer Position Regulator

Provides a center seeking position regulator for dancer

controlled applications.

D2Ć3207

14C237

Shunt Field Supply

Provides a full wave field excitation for shunt wound

DĆC motors. 3 amp capacity included on all drives 2

HP and higher.

-

14C276

M" Contactor Adapter

Provides the interconnecting cable to connect the conĆ

tactor into the regulator sequencing circuit when the

Basic Controller is used.

-

14C293

Contactor Reversing

Second armature contactor and connecting control

cable to convert unidirectional drive into reversing

drive.

D2Ć3293

9C200

Operator's Station

Standard NEMA 4 control station; Start Pushbutton

Stop Pushbutton

Run/Jog Switch

Speed Setting Pot

-

9C300

Operator's Station

Standard NEMA 4 control station; Start Pushbutton

Stop Pushbutton

Run/Jog Switch

Forward/Reverse Switch

Speed Setting Pot

-

9C42

Speed Potentiometer

2 watt, 5K ohm

potentiometer with knob for separate mounting.

-

9C43

Speed Rheostat

4 inch, 5K ohm rheostat with large knob for separate

mounting.

-

9C47

Remote Tork Limit Potentiometer

Remote control of tork limit 10K ohm potentiometer for

separate mounting.

-

9C50

Speed Rheostat with LV1

4 inch, 5K ohm rheostat with large knob for separate

mounting, low voltage interlock.

-

9C55

Automatic - Manual Selector

Switch

Selects Auto/Manual mode of reference source for sepĆ

arate mounting.

-