Rockwell Automation FlexPak Plus DC Drive User Manual
Page 44
Advertising
![background image](/manuals/581666/44/background.png)
5:14
Is
switch in
Manual
position
?
Is
there
continuity
?
Does drive
contain auto
manual
switch
?
D
Yes
No
Done
Fixed?
Yes
No
See Note #1
No
Check wiringof SPD
pot to Remote OperĆ
ator Buffer Kit
Note #1: Contact local sales/service office.
From
previous
2 pages
No
Place in manual
position
Wiring
Correct
?
Replace Operator
SPD pot
Correct Wiring
Done
Fixed?
Yes
No
See Note #1
Check for continuity between
terminal 426 and wiper arm of
Operator SPD pot
E
Correct problem
Done
Fixed?
Yes
No
See Note #1
Yes
Yes
No
E
Yes
DANGER
SOME OF THE FOLLOWING CHECKS AND PROCEDURES REQUIRES THE POWER TO BE ON.
EXERCISE EXTREME CARE AS HAZARDOUS VOLTAGE EXISTS. FAILURE TO OBSERVE THIS
PRECAUTION COULD RESULT IN SEVERE BODILY INJURY OR LOSS OF LIFE.
Figure 5Ć8. M" Contactor PicksĆUp But Motor Does Not Run. (Continued)