Rockwell Automation FlexPak Plus DC Drive User Manual

Page 8

Advertising
background image

2:3

FlexPak Plus

SingleĆPhase DĆC

Controller Description

The Reliance Electric FlexPak Plus

SingleĆPhase DĆC Controller is a

fullĆwave power converter without

back rectifier, complete with an

analog current minor loop and an

analog major loop for armature

voltage or speed regulation by

tachometer feedback. The product

line has been setĆup to be sold as

follows (Refer to Table 2Ć1):
A. BasicChassis Controller without

Auxiliary Panel: Includes power

converter, field supply and

regulator. The Auxiliary Panel

which includes the AĆC power

fuses and armature loop

contactor(s) is not included

when these components are

supplied by others.

B. Complete Chassis Controller

with Auxiliary Panel: Includes the

power converter, field supply

and regulator. The Auxiliary

Panel which includes the AĆC

power fuses and armature loop

contactor(s) is included. This is a

complete packaged drive and is

described in detail in this

manual.

See Table 2Ć2 for Isolation

Transformer Specifications and

Table 2Ć3 for fuse requirements.
In addition, Reliance offers a wide

range of modification kits which

broaden the application range of

the BasicController. These kits are

preĆengineered and all plug into

specific circuits of the Basic

Controller or the Auxiliary Panel. A

summary of these kits is presented

in Table 2Ć4.

Table 2Ć1. Controller Model Numbers

Model Number

Optional

Transf.

KVA

Basic Complete

HP

VAC

AĆC

Amps

(RMS)

DĆC

Arm.

(Volts)

DĆC

Arm.

Amps

Avg.

DĆC

Field

Volts

Amp.

MAX

Power

Supply

Capacity

(2)

MAX

MIN

14C50

14C101

1/4

115

3.5

90

2.5

100

3.0

5000

40.0

0.50

1/3

115

5.2

90

3.7

100

3.0

5000

40.0

0.75

1/2

115

7.0

90

5.0

100

3.0

5000

40.0

1.50

3/4

115

10.5

90

7.5

100

3.0

5000

40.0

1.50

14C51

14C102

1/2

230

3.5

180

2.5

200

3.0

5000

40.0

1.50

3/4

230

5.2

180

3.7

200

3.0

5000

40.0

1.50

1

230

7.0

180

5.0

200

3.0

5000

40.0

2.00

1 1/2

230

10.5

180

7.5

200

3.0

5000

40.0

3.00

14C52

14C103

2

230

14.0

180

10.0

200

3.0

1

5000

40.0

5.00

3

230

21.0

180

15.0

200

3.0

1

5000

40.0

10.0

14C53

14C104

5

230

35.0

180

25.0

200

3.0

1

5000

40.0

10.0

1

Standard

2

Maximum permissible available symmetrical RMS fault current with NEC or CEC external approved disconnect.

Advertising