Rockwell Automation FlexPak Plus DC Drive User Manual
Page 48

A:2
Table AĆ1. Controller Model Numbers
Model Number
Optional
Transf.
KVA
Basic Complete
HP
VAC
AĆC
Amps
(RMS)
DĆC
Arm.
(Volts)
DĆC
Arm.
Amps
Avg.
DĆC
Field
Volts
Amp.
MAX
Power
Supply
Capacity
(2)
MAX
MIN
14C50
14C101
1/4
115
3.5
90
2.5
100
3.0
5000
40.0
0.50
1/3
115
5.2
90
3.7
100
3.0
5000
40.0
0.75
1/2
115
7.0
90
5.0
100
3.0
5000
40.0
1.50
3/4
115
10.5
90
7.5
100
3.0
5000
40.0
1.50
14C51
14C102
1/2
230
3.5
180
2.5
200
3.0
5000
40.0
1.50
3/4
230
5.2
180
3.7
200
3.0
5000
40.0
1.50
1
230
7.0
180
5.0
200
3.0
5000
40.0
2.00
1 1/2
230
10.5
180
7.5
200
3.0
5000
40.0
3.00
14C52
14C103
2
230
14.0
180
10.0
200
3.0
1
5000
40.0
5.00
3
230
21.0
180
15.0
200
3.0
1
5000
40.0
10.0
14C53
14C104
5
230
35.0
180
25.0
200
3.0
1
5000
40.0
10.0
1
Standard
2
Maximum permissible available symmetrical RMS fault current with NEC or CEC external approveddisconnect.
Table AĆ2. Isolation Transformer Specifications.
HP
kVA
Primary Vac
Secondary
Vac
Reliance Part
Number
1/4
0.5
230/460
115
77530Ć16A
0.5
575
115
77530Ć17A
1/3
0.75
230/460
115
77530Ć16B
0.75
575
115
77530Ć17B
1/2Ć3/4
1.5
115
115
77530Ć15D
230/460
115
77530Ć16D
575
115
77530Ć17D
230/460
230
77530Ć16D
575
230
77530Ć17D
1
2.0
230/460
230
77530Ć16E
575
230
77530Ć17E
1Ć1 1/2
3.0
230/460
230
77530Ć16F
575
230
77530Ć17F
2
5.0
230/460
230
77530Ć16G
575
230
77530Ć17G
3Ć5
10.0
230/460
230
77530Ć16H
575
230
77530Ć17H
NOTE: Smaller drives through 3/4 HP @ 115 VAC and 2.0 HP @ 230 VAC may be used with permanent magnetic field motors, and those drive
models are supplied without a DĆC field supply.