102
Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014
Chapter 3
PowerFlex 700H and 700S Drives - Frame 11 Procedures
4.
Remove the appropriate main fan power supply assembly. See
on page
Removing the Main AC or DC Fan Power Supply Assemblies.
5.
Install the new DC fan power supply in the reverse order of removal, using
the existing sheet metal housing.
IMPORTANT
If you are replacing a left-side AC fan inverter circuit board, install the jumper
on connector X3.