D10 Expert

Dual Discrete Outputs

10

P/N 64154 rev. F

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Sensor Setup

• Configures sensor display and operating parameters.

• Click Dynamic (+) or double-pulse remote line to select an option.

• Changes are updated instantly.

• Click Static (-) or single-pulse remote line to advance.

Super-High-Speed Operation Note: Under most conditions, the sensor’s two discrete outputs operate independently. However, the outputs become complementary when
operating at Super-High-Speed, due to its extremely fast response time. Only channel 1 is taught/adjusted; channel 2 is complementary to it (output 1 conducts for the taught ON
condition, and output 2 conducts for the OFF state). To invert these conditions (output 1 – OFF condition, output 2 – ON), change light/dark operate setting.

Push Button

Remote

0.04 sec. ≤ T ≤ 0.8 sec.

Result

Access

SETUP

Mode

• Press and hold
both buttons
concurrently for
> 2 seconds.

• Double-pulse the
remote line.

• Indicator Arrow Icon 1 ON Red

Select

Light/Dark

Operate

• Click Dynamic (+) to
toggle between
selections.

• Double-pulse remote
line to toggle between
selections.

Light Operate:
• Display flashes “lo
• L icon

Dark Operate:
• Display flashes “do
• D icon

• Click Static (-) to save
selection and
advance to
“OFF-Delay.”

• Single-pulse the remote
line to save selection
and advance to
“OFF-Delay.”

Select

OFF-Delay

Timing

Enable

• Click Dynamic (+) to
toggle between
selections.

• Double-pulse the remote
line to toggle between
selections.

OFF (No OFF-Delay):
• “t 0
• Clock icon OFF

2 to 100 ms OFF-Delay:
• “t 2,” “t 5,” “t 10,” “t 15,”
t 20,” “t 30,” “t 40,”
t 60,” “t 80,” or “t100
• Clock icon ON

• Click Static (-) to save
selection and
advance to “Display.”

• Single-pulse the remote
line to save selection
and advance to
“Display.”

Select

Display

Parameters

• Click Dynamic (+) to
toggle between
selections.

• Double-pulse the remote
line to toggle between
selections.

Raw signal value:
• “1234


Percent of excess signal:
• “123P

• Click Static (-) to save
selection and advance
to “Power/Speed.”

• Single-pulse the remote
line to save selection
and advance to
“Power/Speed.”

Select

Speed

and

Power

Combination

• Click Dynamic (+) to
toggle between
selections.

• Double-pulse the
remote line to toggle
between selections.

• Indicator Arrow Icons 1 and 2 ON Red
Super-high-speed
(50-µs response)

• “SHS” (Complementary
outputs; see note below)

High-speed
(200-µs response)

• “HS

High-power
(1-ms response)

• “HP

Super-high-power
(2.5-ms response)

• “SHP

• Return

to RUN
mode.

• Click Static (-) to

save selection and
return to RUN mode.

• Single-pulse the
remote line to save
selection and return
to RUN mode.

• Proceed to

Advanced
Setup

• Quad-click Static

(-) to proceed to
Advanced Setup.

• Quad-click the
remote line to

proceed to
Advanced Setup.

• See Advanced Setup (page 5).

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

dynamic

static

dynamic

static

dynamic

static

dynamic

static

dynamic

static

dynamic

static

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

dynamic

static

dynamic

static

dynamic

static

dynamic

static

T

T

T

T

T

T

T

T

T

T

OR

Advertising