D10 expert, Dual discrete outputs, Single-point dark set – Banner D10 Series User Manual

Page 8: Dark set and light/dark operate selection, Push button, Remote line, Result access set mode, Set output off condition, Figure 10. dark set threshold offset

Advertising
background image

D10 Expert

Dual Discrete Outputs

8

P/N 64154 rev. F

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Figure 9. Single-Point Dark SET (Light

Operate shown)

Sensor positions

window thresholds

≈10%

from the

presented condition

Sensor positions

threshold between

taught conditions

Threshold position

adjusted by

Manual Adjust

Threshold position

adjusted by

Manual Adjust

Sensor positions

threshold between

taught conditions

Sensor positions

threshold slightly below

the presented condition

Sensor positions

threshold slightly above

the presented condition

Darkest

(no signal)

Darkest

(no signal)

Darkest

(no signal)

Most Light

(saturated

signal)

Most Light

(saturated

signal)

Darkest

(no signal)

Most Light

(saturated

signal)

Most Light

(saturated

signal)

Condition

Presented

Sensing window size

adjusted by

Manual Adjust

Output OFF

Output OFF

Output OFF

Output ON

Output ON

Darkest Taught

Condition

Lightest Taught

Condition

Position

adjusted by

Manual Adjust

Output OFF

Output ON

Condition

Presented

Output OFF

Output ON

Condition

Presented

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

2nd Taught

Condition

1st Taught

Condition

Position

adjusted by

Manual Adjust

Push Button

0.04 seconds ≤ “Click” ≤ 0.8 seconds

Remote Line

0.04 seconds ≤ T ≤ 0.8 seconds

Result

Access

SET

Mode

• Press and hold

Static push button
> 2 seconds

• Single-pulse

remote line



• Display flashes “1st
• Arrow icon turns red



• Display flashes “2nd
• Arrow icon turns red

SET

Output

OFF

Condition

• Present Output

OFF condition

• Five-click

Static push
button

• Present Output

OFF condition

• Five-pulse remote line

Threshold Condition Accepted

• Display flashes “sngl” then “dr” twice
• Sensor returns to RUN mode with new settings
• Arrow icon turns green

Threshold Condition Unacceptable

• Display flashes “fail” and returns to “1st
• Arrow icon remains red
• After 60 seconds, sensor returns to RUN mode

(Arrow icon turns green) without changing
settings

T

T T T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T T T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

Push Button

Remote

dynamic

static

dynamic

static

dynamic

static

dynamic

static

dynamic

static

dynamic

static

Mode

Threshold Offset

(counts above

taught signal value)

Super High-Speed

30

High-Speed

22

High-Power

9

Super High-Power

6

Figure 10. Dark SET Threshold Offset

Single-Point Dark SET

• Sets a threshold slightly above the taught condition (see figure 9).
• Any condition lighter than the threshold condition causes the output to change state.
• T

hreshold position is adjustable using “+” and “-” buttons (see Manual Adjust, page 9)

• Recommended for applications where only one condition is known, for example a stable dark

background with varying lighter targets.

A single sensing condition is presented, and the sensor positions a threshold slightly above
the taught condition. When a condition lighter than the threshold is sensed, the output either
turns ON or OFF, depending on the Light/Dark Operate setting (see Sensor Setup, page 10.)

Dark SET and Light/Dark Operate Selection

Dark SET teaches the Output OFF condition and forces the sensor into Light Operate (LO)
mode. The sensor can be reconfigured to Dark Operate (DO) mode after the condition has
been taught (see Sensor Setup, page 10).

Advertising