D10 expert, Dual discrete outputs, Single-point light set – Banner D10 Series User Manual

Page 7: Light set and light/dark operate selection, Push button, Remote line, Result access set mode, Set output off condition, Figure 8. light set threshold offset

Advertising
background image

P/N 64154 rev. F

7

D10 Expert

Dual Discrete Outputs

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Push Button

0.04 seconds ≤ “Click” ≤ 0.8 seconds

Remote Line

0.04 seconds ≤ T ≤ 0.8 seconds

Result

Access

SET

Mode

• Press and hold

Static push button
> 2 seconds

• Single-pulse

remote line



• Display flashes “1st
• Arrow icon turns red



• Display flashes “2nd
• Arrow icon turns red

SET

Output

OFF

Condition

• Present Output

OFF condition

• Four-click

Static push
button

• Present Output

OFF condition

• Four-pulse remote line

Threshold Condition Accepted

• Display flashes “sngl” then “Lt” twice
• Sensor returns to RUN mode with new settings
• Arrow icon turns green

Threshold Condition Unacceptable

• Display flashes “fail” and returns to “1st
• Arrow icon remains red
• After 60 seconds, sensor returns to RUN mode

(Arrow icon turns green) without changing
settings

T

T T T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T T T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

Push Button

dynamic

static

Remote

dynamic

static

dynamic

static

dynamic

static

dynamic

static

Figure 7. Single-Point Light SET (Dark

Operate shown)

Sensor positions

window thresholds

≈10%

from the

presented condition

Sensor positions

threshold between

taught conditions

Threshold position

adjusted by

Manual Adjust

Threshold position

adjusted by

Manual Adjust

Sensor positions

threshold between

taught conditions

Sensor positions

threshold slightly below

the presented condition

Sensor positions

threshold slightly above

the presented condition

Darkest

(no signal)

Darkest

(no signal)

Darkest

(no signal)

Most Light

(saturated

signal)

Most Light

(saturated

signal)

Darkest

(no signal)

Most Light

(saturated

signal)

Most Light

(saturated

signal)

Condition

Presented

Sensing window size

adjusted by

Manual Adjust

Output OFF

Output OFF

Output OFF

Output ON

Output ON

Darkest Taught

Condition

Lightest Taught

Condition

Position

adjusted by

Manual Adjust

Output OFF

Output ON

Condition

Presented

Output OFF

Output ON

Condition

Presented

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

2nd Taught

Condition

1st Taught

Condition

Position

adjusted by

Manual Adjust

Mode

Threshold Offset

(counts below

taught signal value)

Super High-Speed

30

High-Speed

22

High-Power

9

Super High-Power

6

Figure 8. Light SET Threshold Offset

Single-Point Light SET

• Sets a threshold slightly below the taught condition (see Figure 7)
• Any condition darker than the threshold condition causes the output to change state
• T

hreshold position is adjustable using “+” and “-” buttons (see Manual Adjust, page 9)

• Recommended for applications where only one condition is known, for example a stable light

background with varying darker targets.

A single sensing condition is presented, and the sensor positions a threshold slightly below
the presented condition. When a condition darker than the threshold is sensed, the output
either turns ON or OFF, depending on the Light/Dark Operate setting (see Sensor Setup, page
10).

Light SET and Light/Dark Operate Selection

Light SET teaches the Output OFF condition and forces the sensor into Dark Operate (DO)
mode. The sensor can be reconfigured to Light Operate (LO) mode after the condition has
been taught (see Sensor Setup, page 10).

Advertising