D10 expert, Dual discrete outputs, Single-point window set – Banner D10 Series User Manual

Page 6: Window set and manual adjust, Set sensing condition

Advertising
background image

D10 Expert

Dual Discrete Outputs

6

P/N 64154 rev. F

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Push Button

Remote

0.04 sec. ≤ T ≤ 0.8 sec.

Result

Access

SET

Mode

• Press and hold

Static (-) button
> 2 seconds.

• Display flashes “1st
• Arrow icon turns red

• Present sensing condition.
• Single-pulse
the remote line.

• Display flashes “2nd
• Arrow icon turns red

SET

Sensing

Condition

• Present sensing

condition.

• Double-click the

Static button.

• Double-pulse
the remote line.

TEACH conditions acceptable:
• Display flashes “sngl,”
then “pt” twice
• Sensor returns to RUN
mode with new settings.
• Arrow icon turns green

TEACH conditions unacceptable:
• Display flashes “fail” and
returns to “1st
• Arrow icon remains red
• After 60 seconds, sensor
returns to RUN mode
(Arrow icon turns green)
without changing settings.

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

dynamic

static

dynamic

static

dynamic

static

dynamic

static

dynamic

static

dynamic

static

Single-Point Window SET

• Sets a single ON condition that extends 200 counts above and below the taught condition

(including ±100 counts hysteresis)

• All other conditions (lighter or darker) result in OFF output

Sensing window (sensitivity) is adjustable using “+” and “-” buttons (see Manual Adjust,
page 9)

Window SET is most useful when a product may not always appear in the same place, or
when other signals may appear. Window SET designates a sensing window, with the Output
ON condition inside the window, and the Output OFF conditions outside the window (see
Figure 6). The sensor accepts a single sensing condition, and adds switching thresholds and
hysteresis above and below that condition to create a sensing window. Output ON and OFF
conditions can be reversed by changing Light/Dark Operate status in SETUP mode.

Window SET and Manual Adjust

Using Manual Adjust with Window SET expands or contracts the size of the window.

Sensor positions

window thresholds

± 100 counts from the

presented condition

Darkest

(no signal)

Most Light

(saturated

signal)

Taught

Condition

200 counts

Hysteresis

100 counts

Hysteresis

100 counts

Output OFF

Output OFF

Output ON

Sensing window size adjusted by

Manual Adjust

Figure 6. Single-Point Window SET and

Hysteresis (Light Operate shown)