Carrier AQUAZONE PSV User Manual

Installation, start-up, and service instructions, Refrigerant (r-410a)

Advertising
background image

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Catalog No. 04-53500055-01

Printed in U.S.A.

Form 50PS-3SI

Pg 1

7-09

Replaces: 50PS-2SI

Installation, Start-Up, and

Service Instructions

CONTENTS

Page

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . . . . . . 2

GENERAL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31

Step 1 — Check Jobsite

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Step 2 — Check Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

• STORAGE

• PROTECTION

• INSPECT UNIT
Step 3 — Locate Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

• FIELD CONVERSION OF DISCHARGE AIR
Step 4 — Mount the Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . 9

• HORIZONTAL UNIT

• VERTICAL UNITS
Step 5 — Check Duct System

. . . . . . . . . . . . . . . . . . . . . . 9

• SOUND ATTENUATION

• EXISTING DUCT SYSTEM
Step 6 — Install Condensate Drain

. . . . . . . . . . . . . . . . . 9

• HORIZONTAL UNIT

• VERTICAL UNITS

• VENTING
Step 7 — Pipe Connections

. . . . . . . . . . . . . . . . . . . . . . . 10

• WATER LOOP APPLICATIONS

• GROUND-WATER APPLICATIONS

• GROUND-LOOP APPLICATIONS

• INSTALLATION OF SUPPLY AND RETURN HOSE

KIT

Step 8 — Wire Field Power Supply

. . . . . . . . . . . . . . . . 13

• POWER CONNECTION

• SUPPLY VOLTAGE

• 208-VOLT OPERATION

• 460-VOLT OPERATION
Step 9 — Wire Field Controls

. . . . . . . . . . . . . . . . . . . . . 27

• THERMOSTAT CONNECTIONS

• WATER FREEZE PROTECTION

• AIR COIL FREEZE PROTECTION

• ACCESSORY CONNECTIONS

• WATER SOLENOID VALVES

• WSHP OPEN WIRING
Step 10 — Operate ECM Interface Board

. . . . . . . . . . 29

• COOLING

• HEATING

• CFM ADJUST

• DEHUMIDIFICATION MODE
PRE-START-UP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

System Checkout

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

FIELD SELECTABLE INPUTS

. . . . . . . . . . . . . . . . . . 32-35

Complete C Control Jumper Settings

. . . . . . . . . . . . . 32

Deluxe D Control Jumper Settings

. . . . . . . . . . . . . . . . 32

Complete C Control DIP Switches

. . . . . . . . . . . . . . . . . 32

Deluxe D Control DIP Switches

. . . . . . . . . . . . . . . . . . . 32

Units with Modulating Hot Water Reheat

(HWR) Option

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Deluxe D Control Accessory

Relay Configurations

. . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Page

START-UP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35-42

Operating Limits

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

Scroll Compressor Rotation

. . . . . . . . . . . . . . . . . . . . . . .35

Unit Start-Up Cooling Mode

. . . . . . . . . . . . . . . . . . . . . . .35

Unit Start-Up Heating Mode

. . . . . . . . . . . . . . . . . . . . . . .36

Unit Start-Up with WSHP Open Controls

. . . . . . . . . .40

Flow Regulation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41

Flushing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41

Antifreeze

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41

Cooling Tower/Boiler Systems

. . . . . . . . . . . . . . . . . . . .42

Ground Coupled, Closed Loop and Plateframe

Heat Exchanger Well Systems

. . . . . . . . . . . . . . . . . . .42

OPERATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42-46

Power Up Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42

Units with Aquazone Complete C Control

. . . . . . . . .42

Units with Aquazone Deluxe D Control

. . . . . . . . . . . .42

Units with HWR Option

. . . . . . . . . . . . . . . . . . . . . . . . . . . .43

Units with WSHP Open Multiple Protocol

. . . . . . . . . .43

COMPLETE C AND DELUXE D BOARD

SYSTEM TEST

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46,47

Test Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46

WSHP Open Test Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . .47

Retry Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47

Aquazone Deluxe D Control LED Indicators

. . . . . . .47

SERVICE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48,49

Filters

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48

Water Coil

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48

Condensate Drain Pans

. . . . . . . . . . . . . . . . . . . . . . . . . . .48

Refrigerant System

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48

Compressor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48

Fan Motors

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48

Condensate Drain Cleaning

. . . . . . . . . . . . . . . . . . . . . . .48

Air Coil Cleaning

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48

Condenser Cleaning

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48

Checking System Charge

. . . . . . . . . . . . . . . . . . . . . . . . .49

Refrigerant Charging

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

Air Coil Fan Motor Removal

. . . . . . . . . . . . . . . . . . . . . . .49

Replacing the WSHP Open Controller’s

Battery

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

TROUBLESHOOTING

. . . . . . . . . . . . . . . . . . . . . . . . . . .49-57

Control Sensors

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Thermistor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

WSHP Open Controller

. . . . . . . . . . . . . . . . . . . . . . . . . . . .50

Thermostatic Expansion Valves

. . . . . . . . . . . . . . . . . . . 50

Stopped or Malfunctioned ECM Motor

. . . . . . . . . . . . . 54

Moisture Check

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

APPENDIX A — WSHP OPEN SCREEN

CONFIGURATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . .58-63

50PSH,PSV,PSD START-UP

CHECKLIST

. . . . . . . . . . . . . . . . . . . . . . . . . . . . CL-1, CL-2

IMPORTANT: Read the entire instruction manual before

starting installation.

AQUAZONE™

50PSH, PSV, PSD006-070

Single-Stage Water Source Heat Pumps

with PURON

®

Refrigerant (R-410A)

Advertising
This manual is related to the following products: