Fig. 3 — 50psv dimensional data – Carrier AQUAZONE PSV User Manual

Page 6

Advertising
background image

6

a50-8183

R - Configuration Right Return / Top Discharge

- Top View

L - Configuration Left Return / Top Discharge

- Top View

Right Return

- Air Coil Opening

- Right Side View

Left Return

- Air Coil Opening

- Left Side View

NOTES:
1.

Condensate is

3

/

4

-in. FPT copper and is switchable from side to front.

2.

Vertical unit shipped with filter bracket only, extending from unit 2.5-in.
This bracket should be removed for return duct connection.

3.

Discharge flange field installed.

4.

Shaded areas are recommended service areas, not required.

50PSV

UNIT

SIZE

OVERALL

CABINET

(in.)

WATER CONNECTIONS

(in.)

WATER

CONNEC-

TIONS (in.) -
UNITS WITH

HWR

ELECTRICAL
KNOCKOUTS

(in.)

DISCHARGE CONNECTION (in.)

DUCT FLANGE INSTALLED

(±0.10 in.)

RETURN

CONNECTION (in.)

USING RETURN

AIR OPENING

(±0.10 in.)

1

2

3

4

5

Loop

Water

FPT

HWG

FPT

1

2

J

1

/

2

Cond

K

1

/

2

Cond

L

3

/

4

Cond

M

(LH

rtrn)

N

O

Supply

Width

P

Supply

Depth

Q

(RH

rtrn)

R

S

Return

Depth

T

Return

Height

U

A

Width

B

Depth

C

Height

D

In

E

Out

F

HWG

In

G

HWG

Out

H

Conden-

sate

Loop

In D

Loop

Out E

Low

Voltage

Ext

Pump

Power

Supply

006,009,

012

22.4

21.6

34.5

3.7

9.7

N/A

N/A

7.4

1

/

2

N/A

N/A

N/A

3.8

6.3

8.8

6.7

6.3

9.0

9.0

6.7

2.3

17.1

15.3

1.0

018

22.4

25.6

44.6

2.1 10.0

13.9

16.9

7.8

3

/

4

1

/

2

2.1

10.0

3.6

6.1

8.6

7.2

5.8

14.0

14.0

4.9

2.2

21.1

23.2

1.0

024,

030

22.4

25.6

48.5

2.1 10.0

13.9

16.9

7.8

3

/

4

1

/

2

5.26

13.13

3.6

6.1

8.6

7.2

5.8

14.0

14.0

4.9

2.2

21.1

27.2

1.0

036

25.4

30.6

50.5

3.4 10.8

15.6

18.9

7.8

3

/

4

1

/

2

5.96

13.13

3.6

6.1

8.6

6.4

6.3

18.0

18.0

5.3

2.2

26.1

27.2

1.0

042,

048

25.4

30.6

54.5

3.4 10.8

15.6

18.9

7.8

1

1

/

2

5.96

13.13

3.6

6.1

8.6

6.4

6.3

18.0

18.0

5.3

2.2

26.1

31.2

1.0

060,

070

25.4

30.6

58.5

3.4 10.8

15.6

18.9

7.8

1

1

/

2

5.96

13.13

3.6

6.1

8.6

6.4

6.3

18.0

18.0

5.3

2.2

26.1

35.2

1.0

LEGEND

ASP

Alternate Service Panel

BSP

Blower Service Panel

CAP

Control Access Panel

CSP

Compressor Service Panel

FPT

Female Pipe Thread

HWG — Hot Water Generator
HWR — Hot Water Reheat
LH

Left Hand

RH

Right Hand

PSC BLOWER AIRFLOW

CONFIGURATION

CODE

RETURN

DISCHARGE

L

Left

Top

R

Right

Top

Fig. 3 — 50PSV Dimensional Data