Section 3: installation, operation and setup, 01 environment, 02 location – Tweco VAF4 Transmig User Manual

Page 19: 03 ventilation, 04 mains supply voltage requirements, 05 electromagnetic compatibility, Section 3: installation, operation and setup -1, Mains supply voltage requirements -1, Electromagnetic compatibility -1, Transmig vaf4

Advertising
background image

TRANSMIG VAF4

Manual 0-5231

3-1

INSTALLATION, OPERATION AND SETUP

3.01 Environment

These units are designed for use in environments with

increased hazard of electric shock as outlined in IEC

60974.5.
A. Examples of environments with increased hazard of

electric shock are:
1. In locations in which freedom of movement is re-

stricted, so that the operator is forced to perform

the work in a cramped (kneeling, sitting or lying)

position with physical contact with conductive parts.

2. In locations which are fully or partially limited by

conductive elements, and in which there is a high

risk of unavoidable or accidental contact by the

operator.

3. In wet or damp hot locations where humidity or per-

spiration considerably reduces the skin resistance

of the human body and the insulation properties of

accessories.

B. Environments with increased hazard of electric

shock do not include places where electrically conduc-

tive parts in the near vicinity of the operator, which can

cause increased hazard, have been insulated.

3.02 Location

Be sure to locate the wirefeeder according to the fol-

lowing guidelines:
A. In areas, free from moisture and dust.
B. Ambient temperature between 0° C to 40° C.
C. In areas, free from oil, steam and corrosive gases.
D. In areas, not subjected to abnormal vibration or

shock.

E. In areas, not exposed to direct sunlight or rain.
F. The enclosure design of this Wire Feeder meets the

requirements of IP23S as outlined in AS 60529. This

provides adequate protection against solid objects

(greater than 12mm), and direct protection from

vertical drops. Under no circumstances should the

unit be operated or connected in a micro environ-

ment that will exceed the stated conditions. For

further information please refer to AS 60529.

G. Precautions must be taken against the Wire Feeder

toppling over. The Wire Feeder must be located on

a suitable horizontal surface in the upright position

when in use.

SECTION 3: INSTALLATION, OPERATION AND SETUP

3.03 ventilation

!

WARNING

Since the inhalation of welding fumes can

be harmful, ensure that the welding area is

effectively ventilated.

3.04 Mains Supply voltage

Requirements

CAUTION

This wirefeeder cannot be connected directly

to the mains supply. It must be connected

to a suitable wirefeeder control socket on a

power source.

3.05 Electromagnetic Compatibility

!

WARNING

Extra precautions for Electromagnetic

Compatibility may be required when this

Welding Power Source is used in a domestic

situation.

A. Installation and Use - Users Responsibility

The user is responsible for installing and using the

welding equipment according to the manufacturer’s

instructions. If electromagnetic disturbances are

detected then it shall be the responsibility of the user

of the welding equipment to resolve the situation with

the technical assistance of the manufacturer. In some

cases this remedial action may be as simple as earthing

the welding circuit, see NOTE below. In other cases it

could involve constructing an electromagnetic screen

enclosing the Welding Power Source and the work,

complete with associated input filters. In all cases,

electromagnetic disturbances shall be reduced to the

point where they are no longer Trouble-some.

NOTE

The welding circuit may or may not be

earthed for safety reasons. Changing the

earthing arrangements should only be au-

thorised by a person who is competent to

assess whether the changes will increase the

risk of injury, e.g. by allowing parallel weld-

ing current return paths which may damage

the earth circuits of other equipment. Further

guidance is given in IEC 60974-13 Arc Weld-

ing Equipment - Installation and use (under

preparation).