TRANSMIG VAF4

INSTALLATION, OPERATION AND SETUP

3-14

Manual 0-5231

3.09 Wirefeeder Configuration for Different Power Sources

WARNING

There are dangerous voltage and power levels inside this product. Turn OFF wirefeeder and disconnect

from the power source before removing cover from wirefeeder.

The factory default setting for the wirefeeder is set for the Transmig 350i & Transmig 450i power sources. If a

different power source is being used then the user will need to set the Display PCB DIP switch as to Table 3-5

according to the power source being used.

Display PCB

Art # A-11257

DIP Switch

Figure 3-5 DIP Switch on Display PCB

S3S4S5

Vmin

Vmax

Vsetmin(J&K)

Vsetmax(J&K)

Welder

S3=Off(0), S4=Off(0), S5=Off(0)

14

50

3.182

11.364

Transmig 550i

S3=On(1), S4=Off(0), S5=Off(0)

10

44

2.273

10

Transmig 500i

S3=Off(0), S4=On(1), S5=Off(0)

10

36

0

10

Transmig 400i (Refer to

Section 3.24 to override Arc

Establish signal for this welder.

S3=On(1), S4=On(1), S5=Off(0)

14

40

3.182

9.091

Transmig 350i & 450i (default)

S3=Off(0), S4=Off(0), S5=On(1)

15

40

0

-4.8

MPM20/500 & MPM12/400

(Refer to Note)

S3=On(1), S4=Off(0), S5=On(1)

15

30

0

5.5

MPM8/270 & MPM8/255

S3=Off(0), S4=On(1), S5=On(1)

Spare

S3=On(1), S4=On(1), S5=On(1)

8

50

User Type Setting (The

Service Manual outlines

how to set the wirefeeder

for other Power Sources.)

Table 3-5 Voltage Setting

NOTE

When S6=ON(1), calibration functions in Advanced Features Mode is enabled; when S6=OFF(0), cali-

bration functions are disabled.

NOTE

When S1=OFF(0),S2=OFF(0), WFS Setting is applicable for Transmig VAF4 and it ranges from 1.3

MPM to 22.2 MPM.

NOTE

An adaptor cable is required for connection to MPM20/500 or MPM12/400 Engine Drive Power Sources.