Transmig vaf4 – Tweco VAF4 Transmig User Manual

Page 22

Advertising
background image

TRANSMIG VAF4

INSTALLATION, OPERATION AND SETUP

3-4

Manual 0-5231

plication. The value may also be adjusted while a weld is in progress – if this occurs, the left display will briefly

switch to show the adjusted value as the knob is turned, and will automatically revert back to show the weld

current measurements when the knob is not being turned. Turn the left knob either clockwise to increase WFS or

counterclockwise to decrease WFS by increments of 0.1MPM. To increment in steps of 1 MPM whilst holding the

left knob depressed turn it either clockwise to increase WFS or counterclockwise to decrease WFS.
The Left digital meter display option can be changed either via the Advanced Features Menu (refer to Subsection

3.08)
OR

By simply depressing the Left Amps control knob for 3 seconds whilst welding, then by releasing the knob and

then holding it depressed for a further 3 seconds will increment to the next available display option that is shown

on the left digital display. i.e. Amps

WFS

---- (blank).

Press Left Knob (Amps) and Right Knob (Volts) for 1.2 seconds to enter or exit from the advanced programming

mode. Please refer to Subsection 3.08 for Advanced Features Details.
7. Right Knob

Right Knob

The control knob adjusts the output voltage of the power source. The welding voltage is increased by turning the

knob clockwise or decreased by turning the knob counter-clockwise. The value may also be adjusted while a weld

is in progress – if this occurs, the right display will briefly switch to show the adjusted value as the knob is turned,

and will automatically revert back to show the weld voltage measurements when the knob is not being turned.

Turn the right knob either clockwise to increase voltage or counterclockwise to decrease voltage by increments

of 0.1V. To increment in steps of 1V whilst holding the right knob depressed turn it either clockwise to increase

WFS or counterclockwise to decrease WFS.
The Right digital meter display option can be changed either via the Advanced Features Menu (refer to Subsection

3.08)
OR

By simply depressing the Right Amps control knob for 3 seconds whilst welding, then by releasing the knob and

then holding it depressed for a further 3 seconds will increment to the next available display option that is shown

on the right digital display. i.e. VARC

---- (blank).

Press Left Knob (Amps) and Right Knob (Volts) for 1.2 seconds to enter or exit from the advanced programming

mode. In advanced programming mode, turning the knob clockwise to increase and counter-clockwise to decrease

the value on right display. Please refer to Subsection 3.08 for Advanced Features Details.

Advertising