Transmig vaf4 – Tweco VAF4 Transmig User Manual

Page 23

Advertising
background image

TRANSMIG VAF4

Manual 0-5231

3-5

INSTALLATION, OPERATION AND SETUP

8. Left Digital Display

Left display is a 4- digit display.
In advanced programming mode, this display is used to display advanced features details or simply "----". Please

refer to Subsection 3.08 for Advanced Features Details.
When welding, this digital meter will display WFS in Inches Per Minute (IPM) or Metres Per Minute (MPM) and

actual welding amperage of the power source; it can also simply display "----" when the VAF4 is connected to a

power source without a control signal on pin U of the 19 pin interconnection. The VAF4 uses this signal on pin U

of the 19 pin interconnection to display welding amps, if this signal is not present from the power source, set the

display to show "----". Press left knob and select the information on left display. At times of non-welding, the digital

meter will display a pre-set (preview) WFS value. This value can be adjusted by turning the Left Knob (Control No. 6).
At the completion of welding, the digital meter will hold the last recorded value for a period of approximately 10

seconds. The meter will hold the value until: (1) any of the front panel controls are adjusted in which case the

unit will revert to preview mode, (2) welding is recommenced, in which case actual welding amperage will be

displayed, or (3) a period of 10 seconds elapses following the completion of welding in which case the unit will

return to preview mode.
The display is also used for providing error messages to the user. Please refer to Subsection 4.05 for Error Codes

and Remedies.
9. Right Digital Display

Right display is a 4- digit display.
This digital meter is used to display the pre-set (preview) Voltage in MIG mode and actual welding voltage of the

power source or simply "----" when the VAF4 is connected to a power source without a control signal on pin C of

the 19 pin interconnection. The VAF4 uses this signal on pin C of the 19 pin interconnection to display welding

volts, if this signal is not present from the power source, set the display to show "----". Press right knob and select

the information on right display. At times of non-welding, the digital meter will display a pre-set (preview) value

of Voltage. This value can be adjusted by turning the Right Knob (Control No 7).
At the completion of welding, the digital meter will hold the last recorded voltage value for a period of approxi-

mately 10 seconds in all modes. The voltage meter will hold the value until: (1) any of the front panel controls are

adjusted in which case the unit will revert to preview mode, (2) welding is recommenced, in which case actual

welding voltage will be displayed, or (3) a period of 10 seconds elapses following the completion of welding in

which case the unit will return to preview mode.
The display is also used for providing error messages to the user and showing other information. Please refer to

Subsection 4.05 for Error Codes and Remedies.
10. 2T - 4T- SPOT Trigger Mode Control Button

Press and release the button to change the selected operating mode of the trigger. The selected mode can be “2T”,

“4T” or "Spot” operation. The red indicator next to the button will illuminate to identify which mode is selected.

In the 4T mode once the weld has been started you can release the trigger and continue welding until the trigger

is activated again or the welding arc is broken to stop the welding arc. Please refer to Subsection 3.25 - 3.28 for

more details.

Advertising