4.05 Error Codes and remedies

Error Code

Description

Cause

remedy

Left

Display

right

Display

ERR

01--

This protection

circuit is activated

whenever weld

current flows in

the ground fault

protective circuit.

Fault light flashes

at a rate of

approximately 0.5

second ON, 0.5

second OFF.

Weld current is detected

running through the ground

fault protective circuit.

1. Look for metallic dust

build up between the

wirefeed plate assembly/

motor and the Wirefeeder

frame and remove the

metallic dust build up. Turn

OFF Wirefeeder then ON

again to clear ERR 01.
2. If ERR 01 appears

again with the next weld

or metallic dust build up

cannot be located then

contact your Accredited

CIGWELD Service Provider

to investigate the fault.

ERR

02--

Control cable

connecting

Wirefeeder and

Power Source not

correctly connected.

1. 19 pin plug control plug

connection is loose at either

socket on Wirefeeder or

Power Source.
2. Control cable is damaged

or has faulty connection/s.

3. Ensure that the 19 Pin

socket is selected on the

Power Source.

1. Check control cable

connections at the

Wirefeeder and Power

Source are tight.
2. If the Control Cable is

damaged then repair or

replace cable.
3. Check the Power Source

is set to 19 Pin socket

mode.

ERR

03--

Emergency

shutdown

Motor current exceeds

10amps due to seized motor

or clogged liner or filler metal

wire too big for MIG torch

liner or spool hub tension too

tight, etc.

Turn OFF Wirefeeder

then check motor / feed

mechanism can rotate

or replace liner or install

correct size liner for filler

metal or adjust spool hub

tension.
Turn ON Wirefeeder and

if ERR 03 appears again

with the next weld then

contact your Accredited

CIGWELD Service Provider

to investigate the fault.

ERR

04--

Protective shutdown

Motor current exceeds

5amps for 10 seconds due to

clogged liner or filler metal

wire too big for MIG torch

liner or spool hub tension too

tight, etc.

Turn OFF Wirefeeder

then check motor / feed

mechanism can rotate

or replace liner or install

correct size liner for filler

metal or adjust spool hub

tension.
Turn ON Wirefeeder and

if ERR 04 appears again

with the next weld then

contact your Accredited

CIGWELD Service Provider

to investigate the fault.