E. Fit the electrode wire spool to the wire reel hub. Ensure that the wire reel hub alignment pin engages the mating

hole in the wire spool. Push the retaining clip into place to retain the wire spool securely. The electrode wire

should feed from the bottom of the spool.

F MIG Torch Connection (Please refer to Subsection 3.10 & 3.13)
G Lift up the wire feeder pressure levers and pass the electrode wire through the inlet guide, between the rollers,

through the centre guide, between the rollers, through the outlet guide and into the MIG gun.

!

WARNING

DO NOT WEAR GLOVES WHILE THREADING THE WIRE OR CHANGING THE WIRE SPOOL.

H. Lower the pressure levers and with the gun lead reasonably straight, feed the electrode wire through the gun.

Fit the appropriate contact tip, eg a 0.9mm tip for 0.9mm wire.

I Press the INCH button to feed the wire through the gun.

!

WARNING

If the Gun Trigger is used to feed wire through the gun, the electrode wire will be at welding voltage

potential whilst it is being fed through the wirefeeder system.

!

WARNING

Before connecting the work clamp to the work piece make sure the mains power supply is switched off.