Advanced Feature

Left Display

Feature Description

Right Display

Parameter / Selection

Ramp Time

This is used to set the time to ramp

from the creep wire feed speed to

the selected wirefeed speed setting.

Default Ramp Time = 0.2 sec

0.1 to 1.0 seconds

Ramp Time plus Run In is used to optimize arc starting characteristic.

Post Flow

This is used to adjust the post

gas flow time once the arc has

extinguished.

Default Post Flow = 0.1 sec

0.0 – 30 seconds

This control is used to dramatically reduce weld porosity at the completion of the

weld.

Burn Back

This is used to adjust the amount

of MIG wire that protrudes from the

MIG torch after the completion of

MIG welding (commonly referred to

as stick out)

Default Burn Back = 0.15 sec

0.00 to 1.00

seconds

If the Burn Back time is set too long, the MIG wire may burn back to the tip of the

MIG torch.

Crater

This is used to fill in the “crater” at

the end of the weld. It only works

with 4T mode and the Crater Volts /

Crater Wirefeed Speed must be set.

Default Crater = Off

Crater Mode ON /

OFF

Crater Volts

(only if Crater mode is ON)

This sets the reduced volts during

crater operation in 4T at the end of

the weld.

Default Crater Volts = 70%

An example is if Preview Volts is

set to 26V and crater volts is set to

70% crater volts will be 18.2V. Note

minimum crater volts is determined

by minimum preview voltage of

wirefeeder.

0 – 100% of

Welding Volts

Setting

Advertising