Transmig vaf4 – Tweco VAF4 Transmig User Manual

Page 31

Advertising
background image

TRANSMIG VAF4

Manual 0-5231

3-13

INSTALLATION, OPERATION AND SETUP

Advanced Feature

Left Display

Feature Description

Right Display

Parameter / Selection

Restore Factory Defaults

1

This resets all the user adjustable

values in this table (except Arc

Hour Accumulated Runtime) to the

Factory Default Values.

Restore Factory

Default No / YES

caution

Schedule SCH1 & SCH2 settings will be reset to factory default

settings when YES is selected with Restore Factory Defaults.

Exit Advanced Features Mode: by pressing both the left knob and right knob at the

same time for more than 1.2 seconds to Save the Settings and exit advanced features

mode. Note if there has been no user input for 30 seconds, the VAF4 will save settings

and automatically exit advanced programming mode.

Table 3-3 Advanced Features

Factory Default Setting

Factory Default Setting of Non-Schedule: Trigger mode: 2T; Wirefeed speed: 14.0 MPM; Voltage: 26.0V.

Suits Autocraft LW1-6, 0.9mm Hard Wire with Shielding Gas:- 91.9% Ar, 5% CO

2

, 3.1% O

2

.

Factory Default Setting of Schedule 1: Wirefeed speed: 11.5 MPM; Voltage: 29.0V.

Suits Autocraft LW1-6, 1.2mm Hard Wire with Shielding Gas:- 75 - 80% Ar, 20 - 25% CO

2

.

Factory Default Setting of Schedule 2: Wirefeed speed: 9.0 MPM; Voltage: 29.0V.

Suits Verti-Cor 3XP, 1.6mm Flux Cored Wire with Shielding Gas:- 75 - 80% Ar, 20 - 25% CO

2

.

Advanced Feature

Left Display

Feature

Description

Right Display

(Default)

Comments

MIG Control

MIG/CNTR

LOCL

Pre Flow

PRE/FLOW

0.1

Run In

RUN/IN

70

Ramp Time

RAMP/TIME

0.2

Post Flow

POST/FLOW

0.1

Burn Back

BURN/BACK

0.15

Crater

CRAT

OFF

Only in 4T Mode

Crater Volts

CRAT/ VOLT

70

Only when in 4T Mode

and Crater is ON

Crater Wirefeed Speed

CRAT/ WFS

70

Only when in 4T Mode

and Crater is ON

Spot Time

SPOT/TIME

2.0

Only in Spot Mode

Stitch Mode

STCH

OFF

Only in 2T & 4T Modes

Stitch Time

STCH/TIME

2.0

Only when Stitch is ON

Dwell Time

DWEL/TIME

0.5

Only when Stitch is ON

Wirefeed Speed Units

WFS/UNIT

MPM

Left Display Type

LEFT/DISP

AMPS

Right Display Type

RGHT/DISP

VARC

Table 3-4 Factory Default Setting

Advertising