3.07 Rear Panel Controls and Features

16

17

18

19

20

21

Art# A-11256

Figure 3-3 Rear Panel View

16. ON/ OFF Switch

Press this switch to turn ON or turn OFF the Wirefeeder.
17. Gas Inlet

Gas inlet allows to connect the shield gas.
18. Control Cable Socket

The control cable connects to the power source at this

19-pin amphenol connector. It contains the signals re-

quired to allow the welding power source and the wire

feeder to work together as a system.

WARNING

The protective earth ground (pin G) of the

control cable is established ONLY when the

power source is properly grounded. See the

power source owner’s manual for proper

grounding methods.

19. Welding Cable Connector

This connector allows to connect welding cable with

Wirefeeder. Please make sure that it is secured firmly,

or it will heat and generate arc.
20. 4A Circuit Breaker

This circuit breaker protects the wirefeeder from electri-

cal faults on the 115VAC circuit. In the event of a fault

occuring this circuit breaker will trip (pop out). A short

cooling period must be allowed before an attempt is

made to reset it by pressing it back in. Refer to Subsec-

tion 4.08 for further details.

Keyway

A

M

L

K

U

N

B

C

P

V

T

J

H

S

R

D

E

F

G

Figure 3-4 Pin Identification

Control Cable

Pin

Function

A

Contactor + (Shorted to B

to turn ON Power Source)

B

Contactor- (Shorted to A to

turn ON Power Source)

C

Voltage Feedback ( 1

Volt is 10 Arc Volts)

D

Not Used

E

115 VAC Hot

F

42VAC and 115VAC Neutral

G

Protective Earth Ground

H

Remote Control Maximum

J

Remote Control Signal

K

Not Used

L

Power Source Common

M

Arc Established (= +15 VDC)

N

Power Source Select Line

P

Not Used

R

Not Used

S

42VAC Live Wire

T

Not Used

U

Current Feedback (1 Volt

is 100 Arc Amps)

V

Not Used

Table 3-2 Control Cable Pin Functions

21. 8A Circuit Breaker

This circuit breaker protects the wirefeeder from electri-

cal faults on the 42VAC circuit. In the event of a fault

occuring this circuit breaker will trip (pop out). A short

cooling period must be allowed before an attempt is

made to reset it by pressing it back in. Refer to Subsec-

tion 4.08 for further details.